Operating temperature
Template:Short description An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies on the basis of the device's function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature). Outside this range of safe operating temperatures the device may fail.
It is one component of reliability engineering.
Similarly, biological systems remain viable in a temperature range that equates to an operating temperature.
Ranges
Most semiconductor devices are manufactured in several temperature grades. Broadly accepted grades[1] are:
- Commercial: Script error: No such module "convert".
- Industrial: Script error: No such module "convert".
- Military: Script error: No such module "convert".
Nevertheless, each manufacturer defines its own temperature grades, so designers must pay attention to datasheet specifications. For example, Maxim Integrated uses five temperature grades for its products:[2]
- Full Military: Script error: No such module "convert".
- Automotive: Script error: No such module "convert".
- AEC-Q100 Level 2: Script error: No such module "convert".
- Extended Industrial: Script error: No such module "convert".
- Industrial: Script error: No such module "convert".
The use of such grades ensures that a device is suitable for its application and will withstand the environmental conditions in which it is used. Normal operating temperature ranges are affected by several factors, such as the power dissipation of the device.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". These factors are used to define a "threshold temperature" of a device, i.e. its maximum normal operating temperature and a maximum operating temperature beyond which the device will no longer function. Between these two temperatures, the device will operate at a non-peak level.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". For instance, a resistor may have a threshold temperature of Template:Cvt and a maximum temperature of Template:Cvt, between which it exhibits a thermal derating.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
For electrical devices, the temperature of the semiconductor in the device, known as junction temperature, is affected by the ambient temperature, and for integrated circuits is given by the equationScript error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". in which TJ is the junction temperature in °C, Ta is the ambient temperature in °C, PD is the power dissipation of the integrated circuit in W, and Rja is the junction to ambient thermal resistance in °C/W.
Aerospace and military
Electrical and mechanical devices used in military and aerospace applications may need to endure greater environmental variability, including temperature range.
In the United States Department of Defense has defined the United States Military Standard for all products used by the United States Armed Forces. A product's environmental design and test limits to the conditions that it will undergo throughout its service life are specified in MIL-STD-810, the Department of Defense Test Method Standard for Environmental Engineering Considerations and Laboratory Tests.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
The MIL-STD-810G standard specifies that the "operating temperature stabilization is attained when the temperature of the functioning part(s) of the test item considered to have the longest thermal lag is changing at a rate of no more than Script error: No such module "convert". per hour".Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". It also specifies procedures to assess the performance of materials to extreme temperature loads.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
Military engine turbine blades experience two significant deformation stresses during normal service: creep and thermal fatigue.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Creep life of a material is "highly dependent on operating temperature",Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". and creep analysis is thus an important part of design validation. Some of the effects of creep and thermal fatigue may be mitigated by integrating cooling systems into the device's design, reducing the peak temperature experienced by the metal.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
Commercial and retail
Commercial and retail products are manufactured to less stringent requirements than those for military and aerospace applications. For example, microprocessors produced by Intel Corporation are manufactured to three grades: commercial, industrial and extended.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
Because some devices generate heat during operation, they may require thermal management to ensure they are within their specified operating temperature range; specifically, that they are operating at or below the maximum operating temperature of the device.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Cooling a microprocessor mounted in a typical commercial or retail configuration requires "a heatsink properly mounted to the processor, and effective airflow through the system chassis".Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Systems are designed to protect the processor from unusual operating conditions, such as "higher than normal ambient air temperatures or failure of a system thermal management component (such as a system fan)",Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". though in "a properly designed system, this feature should never become active".Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Cooling and other thermal management techniques may affect performance and noise level.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Noise mitigation strategies may be required in residential applications to ensure that the noise level does not become uncomfortable.
Battery service life and efficacy is affected by operating temperature.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Efficacy is determined by comparing the service life achieved by the battery as a percentage of its service life achieved at Script error: No such module "convert". versus temperature. Ohmic load and operating temperature often jointly determine a battery's discharge rate.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Moreover, if the expected operating temperature for a primary battery deviates from the typical 10 °C to 25 °C (Script error: No such module "convert".) range, then operating temperature "will often have an influence on the type of battery selected for the application".Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters". Energy reclamation from partially depleted lithium sulfur dioxide battery has been shown to improve when "appropriately increasing the battery operating temperature".Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
Biology
Mammals attempt to maintain a comfortable body temperature under various conditions by thermoregulation, part of mammalian homeostasis. The lowest normal temperature of a mammal, the basal body temperature, is achieved during sleep. In women, it is affected by ovulation, causing a biphasic pattern which may be used as a component of fertility awareness.
In humans, the hypothalamus regulates metabolism, and hence the basal metabolic rate. Amongst its functions is the regulation of body temperature. The core body temperature is also one of the classic phase markers for measuring the timing of an individual's circadian rhythm.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
Changes to the normal human body temperature may result in discomfort. The most common such change is a fever, a temporary elevation of the body's thermoregulatory set-point, typically by about Script error: No such module "convert".. Hyperthermia is an acute condition caused by the body absorbing more heat than it can dissipate, whereas hypothermia is a condition in which the body's core temperature drops below that required for normal metabolism, and which is caused by the body's inability to replenish the heat that is being lost to the environment.Script error: No such module "Footnotes".Script error: No such module "Check for unknown parameters".
Notes
Page Template:Reflist/styles.css has no content.
Script error: No such module "Check for unknown parameters".
References
Page Template:Refbegin/styles.css has no content.
- Script error: No such module "Citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "Citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".
- Script error: No such module "citation/CS1".