Wetting current
Template:Short description Lua error in package.lua at line 80: module 'Module:Hatnote list' not found. Template:DMCA Template:DMCA In electrical and electronics engineering, wetting current is the minimum electric current needing to flow through a contact to break through the surface film resistance at a contact.[1] It is typically far below the contact's nominal maximum current rating.[2]
A thin film of oxidation, or an otherwise passivated layer, tends to form in most environments, particularly those with high humidity, and, along with surface roughness, contributes to the contact resistance at an interface.[3] Providing a sufficient amount of wetting current is a crucial step in designing circuits that use switches with low contact pressure. Failing to do this might result in switches remaining electrically "open" when pressed, due to contact oxidation.[4][5]
Capacitor discharge solution
In some low voltage applications, where switching current is below the manufacturer's wetting current specification, a capacitor discharge method may be employed by placing a small capacitor across the switch contacts to boost the current through contact surface upon contact closure.[4][6] While this can work, one must also keep the discharge current on contact closure well within the max current rating for the switch. Just putting a cap across a switch without current limiting resistor will result in cumulative contact damage.
Sealing current
A related term sealing current (aka wetting current or fritting current) is widely used in the telecommunication industry describing a small constant DC current (typically 1-20 mA) in copper wire loops in order to avoid contact oxidation of contacts and splices. It is defined in ITU-T G.992.3 for "all digital mode ADSL" as a current flowing from the ATU-C (ADSL Linecard) via the phone lines to the ATU-R (CPE).[7][8] Carbon brushes develop high resistance glaze when they're used without current flow for an extended period. A special circuit is utilized for turbines and generators to introduce current through the brushes into the shaft to prevent this contact fritting.[9]
Contact cleaner
Contact cleaner can be applied to the contact surfaces to inhibit the formation of resistive surface films and/or to ameliorate existing films.[10]
See also
References
- ^ Page Module:Citation/CS1/styles.css has no content.McMillan, Gregory K., ed. (1999). Process/Industrial Instruments and Controls Handbook (5th ed.). McGraw Hill. p. 7.26. ISBN 0-07-012582-1.
- ^ Page Module:Citation/CS1/styles.css has no content."Switch Contact Design - Switches - Electronics Textbook".
- ^ Page Module:Citation/CS1/styles.css has no content.Zhai, C.; Hanaor, D.; Proust, G.; Gan, Y. (2015). "Stress-Dependent Electrical Contact Resistance at Fractal Rough Surfaces" (PDF). Journal of Engineering Mechanics. 143 (3): B4015001. doi:10.1061/(ASCE)EM.1943-7889.0000967.
- ^ a b Page Module:Citation/CS1/styles.css has no content."Relay contact life" (Application note). Winston-Salem, NC, USA: Tyco Electronics Corporation (TEC), P&B Relays. 13C3236, IH/12-00. Archived from the original on 2018-05-19. Retrieved 2018-05-18.
- ^ Page Module:Citation/CS1/styles.css has no content.Mairs, William (September 2004). "Keeping in contact" (PDF). NHP Technical News (42). NHP Electrical Engineering Products Pty. TNL-42 10/04 14M. Archived (PDF) from the original on 2018-05-19. Retrieved 2018-05-19.
- ^ Page Module:Citation/CS1/styles.css has no content.Stewart, Anthony (2011). "The Case of the Intermittent Relay". Design News.
- ^ Page Module:Citation/CS1/styles.css has no content.Recommendation G.992.3: Asymmetric digital subscriber line transceivers 2 (ADSL2). ITU-T. Archived from the original on 2018-05-19. Retrieved 2018-05-19. [1]
- ^ Page Module:Citation/CS1/styles.css has no content.Bennett, Brad (1996-12-13). "Sealing current on ISDN loops". comp.dcom.isdn. Retrieved 2018-05-19.
[…] Wynn Quon: The Bellcore Layer 1 specs talk about "sealing current". This is a low current (1-20mA) DC signal applied to tip and ring. […] It is supposed to reduce oxidation at line splices and it provides a troubleshooting aid in the field. […] Brad Bennett: I was personally the researcher that did the sealing current work while at Bellcore […] sealing current does effectively keep a copper loop intact (through a process called electromigration […] it does work on copper loops which have splices […] for direct copper loops (CO to customer sites) it is ALWAYS supposed to be applied (and is built into the line cards). For other technologies (e.g. BRITE cards), which synthesize ISDN from 3 DS0 circuits at a subscriber loop cabinet (SLC), I am […] not sure it is a requirement. […] other interesting upshots of […] this work, which I am not certain have ever made it to the public. For example there are certain metal pairs [for] which you definitely do NOT want to use sealing current […] or […] run any continuous DC current (e.g. copper and precious metals). Such contacts (splices) are materially designed to fail if current continually flows in the wrong direction. […] on […] copper wires, sealing current helps to maintain good electrical connections […]
- ^ Page Module:Citation/CS1/styles.css has no content.Kiameh, Philip (2003-04-11). Electrical Equipment Handbook : Troubleshooting and Maintenance: Troubleshooting and Maintenance. McGraw Hill Professional. pp. 13–9. ISBN 978-0-07-139603-5.
- ^ Page Module:Citation/CS1/styles.css has no content."Down and Dirty with Contact Cleaners". 2017-02-17.
Further reading
- Page Module:Citation/CS1/styles.css has no content.Pitney, Kenneth E. (2014) [1973]. Ney Contact Manual - Electrical Contacts for Low Energy Uses (reprint of 1st ed.). Deringer-Ney, originally JM Ney Co. ASIN B0006CB8BC. (NB. Free download after registration.)[dead link]
- Page Module:Citation/CS1/styles.css has no content.Slade, Paul G. (2014-02-12) [1999]. Electrical Contacts: Principles and Applications. Electrical engineering and electronics. Vol. 105 (2 ed.). CRC Press, Taylor & Francis, Inc. ISBN 978-1-43988130-9.
- Page Module:Citation/CS1/styles.css has no content.Holm, Ragnar; Holm, Else (2013-06-29) [1967]. Williamson, J. B. P. (ed.). Electric Contacts: Theory and Application (reprint of 4th revised ed.). Springer Science & Business Media. ISBN 978-3-540-03875-7. (NB. A rewrite of the earlier "Electric Contacts Handbook".)
- Page Module:Citation/CS1/styles.css has no content.Holm, Ragnar; Holm, Else (1958). Electric Contacts Handbook (3rd completely rewritten ed.). Berlin / Göttingen / Heidelberg, Germany: Springer-Verlag. ISBN 978-3-662-23790-8.
{{cite book}}: ISBN / Date incompatibility (help) [2] (NB. A rewrite and translation of the earlier "Die technische Physik der elektrischen Kontakte" (1941) in German language, which is available as reprint under Template:ISBN.) - Page Module:Citation/CS1/styles.css has no content.Huck, Manfred; Walczuk, Eugeniucz; Buresch, Isabell; Weiser, Josef; Borchert, Lothar; Faber, Manfred; Bahrs, Willy; Saeger, Karl E.; Imm, Reinhard; Behrens, Volker; Heber, Jochen; Großmann, Hermann; Streuli, Max; Schuler, Peter; Heinzel, Helmut; Harmsen, Ulf; Györy, Imre; Ganz, Joachim; Horn, Jochen; Kaspar, Franz; Lindmayer, Manfred; Berger, Frank; Baujan, Guenter; Kriechel, Ralph; Wolf, Johann; Schreiner, Günter; Schröther, Gerhard; Maute, Uwe; Linnemann, Hartmut; Thar, Ralph; Möller, Wolfgang; Rieder, Werner; Kaminski, Jan; Popa, Heinz-Erich; Schneider, Karl-Heinz; Bolz, Jakob; Vermij, L.; Mayer, Ursula (2016) [1984]. Vinaricky, Eduard; Schröder, Karl-Heinz; Weiser, Josef; Keil, Albert; Merl, Wilhelm A.; Meyer, Carl-Ludwig (eds.). Elektrische Kontakte, Werkstoffe und Anwendungen: Grundlagen, Technologien, Prüfverfahren (in Deutsch) (3 ed.). Berlin / Heidelberg / New York / Tokyo: Springer-Verlag. ISBN 978-3-642-45426-4.
- Page Module:Citation/CS1/styles.css has no content.Lee, Martin (2016-01-11). "Overcome Wetting Voltage and Current Limitations With an External Wetting Power Supply" (PDF) (Application note). Schweitzer Engineering Laboratories, Inc. (SEL). AN20 16-01. Retrieved 2018-05-21.
- Page Module:Citation/CS1/styles.css has no content.Paton, Kevin (2011). The Test, Usage and Maintenance of Power Switching Subsystems (PDF). North Reading, MA, USA: Teradyne, Inc. / IEEE. ISBN 978-1-4244-9363-0. Archived (PDF) from the original on 2017-09-16. Retrieved 2018-05-21.
- Page Module:Citation/CS1/styles.css has no content.El Mossouess, S.; Benjemâa, N.; Carvou, E.; El Abdi, R.; Benmamas, L.; Doublet, L. (2014), Fretting corrosion in power contacts: Electrical and thermal analysis (PDF), archived (PDF) from the original on 2018-05-21, retrieved 2018-05-21